loading

ASNA metering unit

HM Power, a premier ASNA Ring Main Unit manufacturer, 

designs the ASNA metering unit (symbol: M) to accommodate electric energy metering equipment and enable accurate measurement of power consumption. It consists of a busbar compartment, transformer compartment and instrument compartment.


Lead sealing holes are pre-reserved on the upper and lower cabinet doors to avoid unauthorized tampering with the metering circuit.

ASNA metering unit

The ASNA metering unit (symbol: M) is designed to accommodate electric energy metering equipment and enable accurate measurement of power consumption.

It consists of a busbar compartment, transformer compartment and instrument compartment.

Lead sealing holes are pre-reserved on the upper and lower cabinet doors to avoid unauthorized tampering with the metering circuit.

Introduction

Metering Function

Current transformers and voltage transformers are separately mounted within the transformer compartment to supply precise current and voltage signals to energy meter.

Parameter List

Name Unit Parameter
Rated voltage(Ur) kV 12
Rated frequency(fr) Hz 50
Rated continuous current(lr) A 630 1250
Rated short-duration power-frequency withstand voltage(Ud) Common value kV 28
Rated lightning impulse withstand voltage(Up) Common value kV 75
Rated short-time withstand current(Ik) kA 20 /25 20/25/31.5
Rated short-time of short-circuit(tk) s 4
Rated peak withstand current(Ip) kA 50 / 63 50/63/80
Degree of protection by enclosure   IP 4X
Degree of protection by fully sealed tank   IP 65
Dimensions Low voltage chamber not included W(mm) 810 1000
D(mm) 860 900
H(mm) 1640 1810

Application

National Little Giant Recognition: HM POWER's Journey as a China Top Insulated RMU Manufacturer
In China's industrial policy framework, the designation of "National Little Giant" enterprise carries a specific and demanding meaning. The ...
Italy PCS Energy Storage Integrated Unit Power Distribution Project
Italy has witnessed rapid growth in installed capacity of wind and solar new energy, with steadily rising demand for energy storage on both grid-side and commercial & industrial sides. By charging and discharging to implement peak shaving and valley filling, energy storage systems effectively smooth grid fluctuations and reduce power consumption costs. As a critical component for grid connection, the medium-voltage switchgear supporting energy storage power stations is subject to growing attention on environmental compliance. Relevant EU greenhouse gas control regulations impose mandatory constraints on equipment selection. The EU F-Gas Regulation (EU) 2024/573 clearly stipulates that SF₆ greenhouse gas shall be prohibited for new medium-voltage switchgear with rated voltage ≤24kV starting from 1 January 2026.
Power Distribution Project of Tanzania Sapphire Float Glass Industrial Park
The Tanzania Sapphire Float Glass Industrial Park is a benchmark project under China’s Belt and Road Initiative. The glass manufacturing process imposes extremely stringent requirements on power supply continuity, power quality and voltage stability. Meanwhile, the park features complex operating conditions including high temperature, high humidity, dust and tin fog corrosion, which pose severe challenges to the corrosion resistance and long-term operational reliability of power distribution equipment.
Smart City Distribution Project in Stockholm, Sweden
Stockholm, Sweden, is a benchmark for smart city and green low-carbon urban development in Northern Europe. It was awarded the world’s first "European Green Capital" title in 2010. As a key supporting initiative for the grid intelligence and urban low-carbon transition of Stockholm, this smart city power distribution project comprehensively improves the stability and environmental performance of urban public power supply and serves as an important pillar for long-term sustainable development.
Tesla Supercharger Station Power Distribution Project, Sweden
In 2014, the first batch of Tesla Superchargers in Västerås, Sweden, supporting this project was completed and put into operation. It serves as a highly representative energy replenishment infrastructure for new energy vehicles in Northern Europe. As a high-power dynamic electrical load scenario, the supercharger station imposes stringent requirements on the 10kV distribution system in terms of power supply reliability, equipment stability, fault handling capability and low-carbon compliance.
Power Distribution Project of Hainan Wenchang Space Launch Site
The commercial Wenchang Space Launch Site is located on the coast of Hainan, featuring year-round high humidity and salt spray. Its core power distribution room supports uninterrupted critical services including launch telemetry & control, command communication and data computation. It imposes aerospace-grade stringent requirements far exceeding ordinary industrial standards on the safety level of the power distribution system, power supply continuity, environmental weather resistance and long-period maintenance-free performance.
Haikou Meilan International Airport Phase II Expansion · ATC Station Room Renovation Project
As the core aviation hub of the Hainan Free Trade Port, Haikou Meilan International Airport undertakes key functions including passenger and cargo transportation as well as air traffic control (ATC) navigation support. The ATC station room renovation required an upgrade of the power distribution system under non-stop flight and uninterrupted ATC service conditions. The project demands absolutely continuous and secure power supply, while the equipment must adapt to on-site conditions featuring densely arranged devices and complex electromagnetic environments.
Tencent Data Center Power Distribution Project, Guizhou
Tencent Data Center in Guizhou is China’s first large-scale cave-type data center, undertaking core services including data storage and AI training. Power outages may result in data loss and computing capacity loss, so extremely high reliability requirements are imposed on power supply. Its unique geographic location also raises stringent requirements for anti-condensation performance and maintenance-free operation.
Qualification

Certification And Qualification

Questions and answered

1
Q: What are the standard accuracy classes for CTs and PTs fitted in metering cabinet (M unit)?
A: It is recommended that the CT accuracy class be 0.2S and the PT accuracy class be 0.2 to comply with IEC standards.
contact us

Let's get in touch!

No matter which stage your project is at, our professional team of engineers can provide you with full-process professional support from product selection, solution design, factory visits to delivery and maintenance.

phone
+86 18138383310
email
sales@hmpower-global.com

contatc us

Copyright © 2026 HM Power (Guangdong) Co., Ltd. | Sitemap
弹窗效果

HM Power to Present Zero-SF₆ RMU Solutions at All Energy Australia 2026

To make the most of your time at the show, we recommend scheduling a dedicated meeting slot in advance. Simply complete the form, and our team will confirm your booking before the exhibition.
Customer service
detect